Price includes the following:

*A Bryant Legacy 2.5 Ton Up to 16 SEER2 Air Conditioner Model # 115SAN03000W 

*One of the 2 following Bryant/Carrier Evaporator Coils (Vertical application only)

*Model # CVPVA3017XMC (17.5 inch wide/19.4375 inch high)

*Model # CVPVA3014XMC (14.1875 inch wide/17.0625 inch high)

 One of the following Bryant Condensing Gas Furnaces (Vertical application only)

*Model # 915SB30040E14 (14 inch wide/35 inch high, 95% AFUE, 40000 btu)

*Model # 915SB36040E17 (17.5 inch wide/35 inch high, 95% AFUE, 40000 btu)

*Model # 915SB42060E17 (17.5 inch wide/35 inch high, 95% AFUE, 60000 btu)

*Model # 926TB30040V14 (14.19 inch wide/35 inch high) 96% AFUE, 40000 btu)

*Model # 926TB36040V17 (17.5 inch wide/35 inch high, 96% AFUE, 40000 btu)

*Model # 926TB42060V17 (17.5 inch wide/35 inch high, 96% AFUE, 60000 btu)

*We will choose one of the previous models listed based on your selection in the dropdown for Coil/Furnace width, and AFUE

*Removal of old refrigerant from existing equipment (Refrigerant recovery)

*Removal and haul away of old air conditioner and related debris

*Removal and haul away of old evaporator coil and related debris

*Removal and haul away of olf furnace and related debris

*New 30x30 or 32x32 inch air conditioner pad

*Leveling ground for new air conditioner pad

*Placement of New Bryant 2 ton air conditioner on new air conditioner pad 

*Copper refrigerant pipe connections right at the air conditioner and right at the evaporator coil using the existing lineset(refrigerant pipes).

*R11 flush to clean out old refrigerant and oils out of the existing lineset 

*Copper refrigerant fittings needed to connect air conditioner and evaporator coil to existing lineset

*New black rubbatex insulation for suction pipe up to 6 feet at the air conditioner and up to 6 feet at the evaporator coil

*3/8 single direction filter drier

*Brazing by use of Oxy/Acetylene torch and low pressure nitrogen

*Nitrogen pressure test 

*Evacuation by use of vacuum pump

*High and low voltage wiring connections at air conditioner

*High and low voltage wiring connections at the furnace

*Gas pipe connections at furnace 

*Sheet metal duct transition at evaporator coil up to 1.5 feet in height only in accessible areas

*Silver taping at the top and bottom of the evaporator coil

*Silver taping at furnace/coil connection and furnace and return duct connection

*Silver taping duct joints for new duct transition or box if required to make transition or box

*Condensate drain piping for the evaporator coil and furnace using 3/4-inch pvc pipe and fittings up to 10 feet

*Reconnect flu pipe to new furnace using new 2 inch pvc pipe and fittings

*Open service valves

*Test A/C

*Test Heat 

*Add additional 410a refrigerant as needed to reach optimum subcooling and superheat levels

*PRICE INCLUDES INSTALLATION AND LABOR COST

*5 Year unregistered parts warranty

*10 YEAR REGISTERED PARTS WARRANTY (The customer is required to register the model and serial numbers of their new air conditioner and evaporator coil within 30 days of the install date in order to recieve the full 10 year parts warranty). Failure to register the equipment will result in a 5 year manufacturer parts warranty. Equipment can be registered at: https://productregistration.bryant.com

*Drymount Air 2 YEAR LABOR WARRANTY

*Price does not include new thermostat or labor to replace thermostat unless a thermostat has been selected in the thermostat option drop down at the top of this page. 