Price includes the following:

*A Bryant Legacy 5 ton SEER2 Air Conditioner Model # 115SAN06000W

*One of the following Bryant/Carrier Evaporator Coils (Vertical application only)

*Model # CVPVA6024XMC (24.5 inch wide/ 26.3125 inch high)

*Model # CVPMA6021XMC (21 inch wide/30.2812 inch high)

*One of the following Bryant 80% \ Gas Furnaces (Vertical application only)

*Model #800SB60110M21 (21 inch wide/33.3333 inch tall, 80% AFUE 110,000 btu input)

*Model # 800SA60110E24 (24.5 inch wide/33.25 inch tall, 80% AFUE 110,000 btu input)

*Model # 800SA60135E24 (24.5 inch wide/33.3333 inch tall, 80% AFUE 135,000 btu input)

*Model # 800SA60155E24 (24.5 inch wide/33.3333 inch tall, 80% AFUE 155,000 btu input)

* We will choose one of the previously listed furnace models based on your selection made in the dropdown for AFUE

*Removal of old refrigerant from existing equipment (Refrigerant recovery)

*Removal and haul away of old air conditioner and related debris

*Removal and haul away of old evaporator coil and related debris

*Removal and haul away of olf furnace and related debris

*New 32x32 inch air conditioner pad

*Leveling ground for new 32x32 inch air conditioner pad

*Placement of New Bryant 4 ton air conditioner on new 32x32 inch air conditioner pad

*Copper refrigerant pipe connections right at the air conditioner and right at the evaporator coil using the existing lineset(refrigerant pipes).

*R11 flush to clean out old refrigerant and oils out of the existing lineset

*Copper refrigerant fittings needed to connect air conditioner and evaporator coil to existing lineset

*New black rubbatex insulation for suction pipe up to 6 feet at the air conditioner and up to 6 feet at the evaporator coil

*3/8 single direction filter drier

*Brazing by use of Oxy/Acetylene torch and low pressure nitrogen

*Nitrogen pressure test

*Evacuation by use of vacuum pump

*High and low voltage wiring connections at air conditioner

*High and low voltage wiring connections at the furnace

*Gas pipe connections at furnace

*Sheet metal duct transition at evaporator coil up to 1.5 feet in height only in accessible areas

*Silver taping at the top and bottom of the evaporator coil

*Silver taping at furnace/coil connection and furnace and return duct connection

*Silver taping duct joints for new duct transition or box if required to make transition or box

*Condensate drain piping for the evaporator coil and furnace using 3/4-inch pvc pipe and fittings up to 10 feet

*Reconnect flu pipe to new furnace

*Open service valves

*Test A/C

*Test Heat

*Add additional 410a refrigerant as needed to reach optimum subcooling and superheat levels

*PRICE INCLUDES INSTALLATION AND LABOR COST

 

*Price does not include new thermostat or labor to replace thermostat unless a thermostat has been selected in the thermostat option drop down at the top of this page.

5 Ton Bryant Legacy Air Conditioner, Evaporator Coil w/ 80% Furnace

$10,500.00Price
    Product Page: Stores Product Widget
    bottom of page